Operating instructions

Language Dictionary
42
Returned Parameters
< NRl > CHAN? returns number of channel presently selected.
CHAN? MAX returns the number of channels installed in the multiple
electronic load. If none are installed, 0 is returned. For single electronic
loads CHAN? MAX returns 1. CHAN? MIN always returns 1 for
either single or multiple loads.
Suffix
None
Related Commands
None
Alternate Syntax
INSTrument can be used as an alias for CHANnel.
CURRent Subsystem Channel-Specific Current Programming Function
Description
This subsystem programs the CC (constant-current mode) function of a single electronic
load or a single channel of a multiple electronic load.
Keywords
Command
CURRent[:LEVel][:IMMediate]
CURRent[:LEVel] :TRIGgered
Function
Specify the input current level for the CURRent mode.
Preset a new input current level to be valid when a trigger occurs.
CURRent:PROTection[:LEVel]
Set current limit at which protection occurs.
CURRent:PROTection:DELay
Set time for which protection current limit may be exceeded.
CURRent:PROTection:STATe OFF|0
Disable protection function.
CURRent:PROTection:STATe ON|1
Enable protection function.
CURRent:RANGe
Specify full-scale input current range.
CURRent:SLEW
Specify the current level rate of change for all current ranges and for the
middle and maximum resistance ranges.
CURRent:TLEVel Specify input current level used with the TRANsient Subsystem.
Related Subsystems
RESistance VOLTage