Specifications
E36xxA: Making Adjustments With the Output Disabled
Question: How do I adjust the voltage or current settings when the Output is disabled on an E36xxA-Series power
supply?
Answer: When the Output is disabled, press the 'Display Limit' button on the front panel to place the power supply
in the limit mode. Then, set the desired limit values for the output voltage and/or current. Press the 'Output Off'
button again to enable the power supply's output.