Specifications

Master current = 14.55A
Each slave current = -14.55A / 2 = -7.28A
Iout = 0A
All 668xA power supplies have an output current programmed at ac power-on. The default current value
programmed at power-on can be found in table 3-1 of Programming Guide 5960-5597. See *RST and *SAV in the
programming guide to change the power-on current value.
A current programmed via the rear panel +Ip / -Ip inputs will be summed with a current programmed via the front
panel keypad or GPIB. When programming slave supplies via the rear panel +Ip / -Ip inputs all slave supply current
programming values must be zero ( 0 ).
Q Analog Connector R Slave Supply S Master Supply
TProgram only the master. Set slave output and OVP voltage slightly higher than the master to ensure that slave stays in
CC mode
U Load V Load Connection
A Only local sensing permitted
B
Connect for remote sensing (optional)