Product specifications

78
Low-Profile Modular Power System
20-500 W GPIB (Continued)
Sp ecifica ti on s
(at 0° to 55°C, and
derated above 40°C)
M
ore detailed specifications at
www.agilent.com/find/N6700
High Performance DC Power Supplies speed and accuracy for test optimization
N6761A N6762A N6763A N6764A N6765A N6766A
1
Output current is derated 1% per °C above 40°C.
2
Applies when measuring 4096 data points (SENSe:SWEep:POINts = 4096).
3
Applies when measuring currents that remain within the low range. Due to thermal settling, when transitioning
from measuring full-rated output current (the worst case), to measuring the current within the low range, the
low range accuracy specification is typically met within 5 seconds after the current has transitioned into the
low range. Accuracies within this 5 second settling period are typically 2X the specified accuracy or better.
DC output ratings
Voltage 50 V 50 V 20 V 60 V 20 V 60 V
Current
1
1.5 A 3 A 50 A 20 A 50 A 17 A
Power 50 W 100 W 300 W 300 W 500 W 500 W
Low programming ranges (V & I) 5.5 V; 5.5 V; N/A N/A N/A N/A
100 mA 100 mA
Low measurement ranges (V & I) 5.5 V; 5.5 V; 2 V; 6 V; 2 V; 6 V;
100 mA 100 mA 1.5 A 0.5 A 1.5 A 0.5 A
Programming accuracy
(at 23°C ±5°C after 30 minute warm-up. Applies from minimum to maximum programming range)
Voltage, high range 0.016% + 0.016% + 0.03% + 0.03% + 0.03% + 0.03% +
6 mV 6 mV 5 mV 12 mV 5 mV 12 mV
Voltage, low range 0.016% + 0.016% + N/A N/A N/A N/A
1.5 mV 1.5 mV
Current, high range 0.04% + 0.04% + 0.1% + 0.075% + 0.1% + 0.075% +
200 µA 200 µA 15 mA 4 mA 15 mA 4 mA
Current, low range (@ 0-7 V) 0.04% + 0.04% + N/A N/A N/A N/A
30 µA 30 µA
(@ 7-50 V) 0.04% + 0.04% +
55 µA 55 µA
Voltmeter/ammeter measurement accuracy
(at 23°C ±5°C)
Voltage, high range 0.016% + 0.016% + 0.03% + 0.03% + 0.03% + 0.03% +
6 mV 6 mV 10 mV 25 mV 10 mV 25 mV
Voltage, low range 0.016% + 0.016% + 0.03% + 0.03% + 0.03% + 0.03% +
1.5 mV 1.5 mV 1.5 mV 5 mV 1.5 mV 5 mV
Current, high range 0.04% + 0.04% + 0.1% + 0.1% + 0.1% + 0.1% +
160 µA 160 µA 10 mA 5 mA 10 mA 5 mA
Current, low range 0.03% + 0.03% + 0.05% + 0.05% + 0.05% + 0.05% +
15 µA 15 µA 1.1 mA
3
0.75 mA
3
1.1 mA
3
0.75 mA
3
(@ 0-7 V)
2
(@ 0-7 V)
2
0.03% + 0.03% +
55 µA 55 µA
(@ 7-50 V) (@ 7-50 V)
200 µA current range (option 2UA) 0.5% + 0.5% + N/A N/A N/A N/A
100 nA 100 nA
Output ripple and noise (PARD): (from 20 Hz to 20 MHz)
CV peak-to-peak 4.5 mV 4.5 mV 5 mV 6 mV 5 mV 6 mV
CV rms 0.35 mV 0.35 mV 1 mV 1 mV 1 mV 1 mV
Load effect (Regulation): (Applies for any output load change, with a maximum load-lead drop of 1 V/ lead.
The load lead drop reduces the maximum available voltage at the load.)
Voltage 0.5 mV 0.5 mV 2 mV 2 mV 2 mV 2 mV
Current 30 µA 30 µA 12 mA 5 mA 12 mA 5 mA
(@ 0-7 V) (@ 0-7 V)
65 µA 65 µA
(@ 7-50 V) (@ 7-50 V)
Series and parallel operation
To increase the available power,
identical models can be operated
in series for g reater output voltage
or in parallel for greater output
current.
To simplify parallel operation, the
N6700 offers virtual channels, a
firmware based feature that allows
the N6700 system to treat up to
4 channels as a single, synchronized
channel. Once confi gured, all func-
tions (sourcing, measurem ents,
triggering, protection, and status
monitoring) behave as if there is
1 channel of up to 4 times t he
capacity of a single channel, with-
out writing a single line of code
to manage the interaction and
synchron ization of the paralleled
power supplies.
Triggering
The N6700 MPS mainframe has
hardware trigger in/trigger out sig-
nals which permit the N6700 to be
synchron ized with external events.
Output disconnect relays
Modules in the N6700 can be
individually ordered with optional
Output Disconnect Relays (optio n
761) or Output Disconnect/Polarity
Reversal Relays (option 760). With
option 761, Output Disconnect Relays,
mechanical relays disconnec t both
the plus and minus side of the
power sup ply, including the sense
leads . With o ption 760, Output
Disconnect/Polarity Reversal Relays
switch the leads on both the plus
and minus side of the power
supply, including the sense leads,
resulting in a voltage polarity
reversal at the DUT.