Technical data
84
Notes:
1. Operating temperature range is
0° to 55°C. All specifications apply
for 25°C ±5°C, except as noted.
2. Maximum continuous power
available is derated linearly from
40°C to 75% of maximum at 55°C.
3. dc current accuracy specifications
apply 30 seconds after input
is applied.
Supplemental Characteristics
for all model numbers
Weight: 6.12 kg (13.5 lb) net; 8.16 kg
(18 lb) shipping
Size: 425.5 mm W x 88.1 mm H x
396 mm D (16.75 in x 3.5 in x 13.7 in )
See page 100 for more details.
Ordering Information
Opt 020 Front Panel dc Input Connectors
Opt 100 87 to 106 Vac, 47 to 66 Hz input
(for Japan only)
Opt 120 104-127 Vac, 47 to 66 Hz
Opt 220 191 to 233 Vac, 47 to 66 Hz input
Opt 240 209 to 250 Vac, 47 to 66 Hz input
* Opt 908 Rack-mount Kit (p/n 5063-9212)
* Opt 909 Rack-mount Kit with Handles
(p/n 5063-9219)
Opt 0B0 no manuals included
Opt 0L2 additional set of standard
documentation
Opt 0B3 Service Manual
* Support rails required
Accessories
E3663AC Support rails for Agilent
rack cabinets
Single-Input: 250 W to 300 W (Continued)
Specifications
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent dc Electronic Loads maximize throughput with real-life loading conditions
6060B 6063B
Supplemental Characteristics (Non-warranted characteristics determined by design that are
(Continued)
useful in applying the product)
Analog monitor accuracy
Current monitor (0 to 10 V out) 4% ±85 mA 3% ±10 mA
Temperature coefficient 50 ppm/°C ±6 mA/°C 100 ppm/°C ±1 mA/°C
Voltage monitor (0 to 10 V out) 0.25% ±40 mV 0.4% ±240 mV
Temperature coefficient 50 ppm/°C ±0.2 mV/°C 70 ppm/°C ±1.2 mV/°C
Remote sensing 5-Vdc maximum between 5-Vdc maximum between
sense and load input sense and load input
Minimum operating voltage 2 volts (1.2 V typical) 2 volts (1.2 V typical)
(at full rated current)
Programmable short 0.033 Ω (0.020 Ω typical) 0.20 Ω (0.10 Ω typical)
Programmable open (typical) 20 kΩ 80 kΩ
Drift (over 8-hour interval)
Current 0.03% ±10 mA 0.03% ±15 mA
Voltage 0.01% ±10 mV 0.01% ±20 mV
dc isolation voltage ±240 Vdc, between any ±240 Vdc, between any
input and chassis ground input and chassis ground
Digital inputs V
IL
= 0.9 V max at I
IL
=V
IL
= 0.9 V max at I
IL
=
–1 mA / V
IH
= 3.15 V min –1 mA / V
IH
= 3.15 V min
(pull-up resistor on input) (pull-up resistor on input)
Digital outputs V
OL
= 0.72 V max at I
OL
=V
OL
= 0.72 V max at I
OL
=
1 mA / V
OH
= 4.4 V min 1 mA / V
OH
= 4.4 V min
at I
OH
= –20 µA at I
OH
= –20 µA
Net weight (approx.) 6.12 kg (13.5 lb) 6.12 kg (13.5 lb)