Technical data

Supplemental Characteristics
for all model numbers
Analog Programming Bandwidth:
10 kHz (-3 db frequency)
Analog Programming Voltage:
Voltage: 0 - 10 V
Current: 0 - 10 V
Analog Monitor Ports:
Voltage: 0 - 10 V
Current: 0 - 10 V
Remote Sensing:
5 V dc between sense and load input
Digital/Trigger Inputs
Vil = 0.9 V max at Iil = -1 mA
Vih - 3.15 V min
(pull-up resistor on input)
Digital/Trigger Outputs
Vol = 0.72 V max at Iol = 1 mA
Voh = 4.4 V min at Ioh = -20 µ A
Size:
See page 106 for more details.
Net Weight:
N3300A: 13.2 kg (29 lb); N3301A: 7.3 kg
(16 lb); N3302A, N3303A or N3304A: 2.7 kg
(6 lb); N3305A or N3306A: 4.6 kg (10 lb),
N3307A 2.7 kg (6 lb)
Shipping Weight:
N3300A: 17 kg (38 lb); N3301A: 9.1 kg (20 lb)
N3302A, N3303A, or N3304A: 4.1 kg (9 lb)
N3305A or N3306A: 6.8 kg (15 lb), N3307A
4.1 kg (9 lb)
81
Multiple-Input: 150 W to 600 W (Continued)
N3300A N3301A
Operating temperature range 0°C to 55°C 0°C to 55°C
Input ratings
Operating range 100 - 250 Vac 100 - 250 Vac
48 - 63 Hz 48 - 63 Hz
Input Current 4.2 A @ 100 - 127 Vac 2.3 A @ 100 - 250 Vac
2.2 A @ 200 - 250 Vac
Input VA 440 VA 230 VA
Inrush Current 38 A 18 A @ 115 Vac
36 A @ 230 Vac
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent dc Electronic Loads maximize throughput with real-life loading conditions
Table A-3
Supplemental Characteristics
Ordering Information
Opt. UJ1: 8 mm screw terminal
connector (available on all load
modules N3302A-N3307A)
Opt. 800: Rack-mount kit for two N3301A
Mainframes mounted side-by-side
(p/n 5061-9694 and 5062-3978).
Opt. 908: Rack-mount kit (Two p/n 5062-3974
for a N3300A, or p/n 5062-3960
for one N3301A). For the N3301A,
the kit includes a blank filler panel.
Opt. 909: Rack-mount kit with handles for
N3300A (Two p/n 5062-3975)
Opt. 0B0: no manuals included (available
with N3300A and N3301A)
Opt. 0L2: additional set of manuals