Technical data

78
Multiple-Input: 150 W to 600 W (Continued)
Table A-1 Specifications
Table A-1 lists the specifications
for the different load models.
Specifications indicate warranted
performance in the 25°C ±5°C
region of the operating temperature
range. Specifications apply to
normal and transient modes
unless otherwise noted.
Input Characteristic
Notes
1
Maximum continuous power available
is derated linearly from 100% of
maximum at 40°C, to 75% of maximum
at 55°C.
2 Specification is ± (% of reading + fixed
offset). Measurement is 1000 samples.
Specification may degrade when the
unit is subject to an RF field of
3 V/meter, the unit is subject to
line spikes of 500 V, or an 8 kV
electrostatic discharge.
3 dc current accuracy specifications
apply 30 seconds after input current
is applied.
N3302A N3303A N3304A N3305A N3306A N3307A
Input ratings
Current 0 - 30 A 0 - 10 A 0 - 60 A 0 - 60 A 0 - 120 A 0 - 30 A
Voltage 0 - 60 V 0 - 240 V 0 - 60 V 0 - 150 V 0 - 60 V 0 - 150 V
Maximum Power @ 40°C
1
150 W 250 W 300 W 500 W 600 W 250 W
Specified current @
low voltage operation
2.0 V 30 A 10 A 60 A 60 A 120 A 30 A
1.5 V 22.5 A 7.5 A 45 A 45 A 90 A 22.5 A
1.0 V 15 A 5 A 30 A 30 A 60 A 15 A
0.5 V 7.5 A 2.5 A 15 A 15 A 30 A 7.5 A
0 V 0 A 0 A 0 A 0 A 0 A 0 A
Typical minimum operating Table A-1 states that maximum current is available down to 2 volts. Typically,
voltage @ full scale current however under normal operating conditions, the load can sink the maximum
current down to the following voltages:
1.2 V 1.2 V 1.2 V 1.4 V 1.4 V 1.4 V
Constant current mode
2
Low Range/High Range 3 A/30 A 1 A/10 A 6 A/60 A 6 A/60 A 12 A/120 A 3 A/30 A
Regulation 10 mA 8 mA 10 mA 10 mA 10 mA 10 mA
Low Range Accuracy 0.1% + 5 mA 4 mA 7.5 mA 7.5 mA 15 mA 7.5 mA
High Range Accuracy 0.1% + 10 mA 7.5 mA 15 mA 15 mA 37.5 mA 15 mA
Constant voltage mode
2
Low Range/High Range 6 V/60 V 24 V/240 V 6 V/60 V 15 V/150 V 6 V/60 V 15 V/150 V
Regulation 5 mV 10 mV 10 mV 10 mV 20 mV 10 mV
Low Range Accuracy 0.1% + 3 mV 10 mV 3 mV 10 mV 3 mV 10 mV
High Range Accuracy 0.1% + 8 mV 40 mV 8 mV 20 mV 8 mV 20 mV
Constant resistance mode
2
Range 1 (I >10% of current rating) 0.067-4 0.2-48 0.033-2 0.033-5 0.017-1 0.067-10
Range 2 (I >1% of current rating) 3.6-40 44-480 1.8-20 4.5-50 0.9-10 9-100
Range 3 (I >0.1% of current rating)
36-400 440-4800 18-200 45-500 9-100 90-1000
Range 4 (I >0.01% of current rating)
360-2000 4400-12000 180-2000 450-2500 90-1000 900-2500
Transient generator
Frequency Range
0.25 Hz- 0.25 Hz- 0.25 Hz- 0.25 Hz-
0.25 Hz 0.25 Hz-
10 kHz 10 kHz 10 kHz 10 kHz
10 kHz 10 kHz
Pulse Width
50 µs ±1% to 50 µs ±1% to 50 µs ±1% to 50 µs ±1% to 50 µs ±1% to 50 µs ±1% to
4 seconds ±1% 4 seconds ±1% 4 seconds ±1% 4 seconds ±1% 4 seconds ±1% 4 seconds ±1%
Current measurement
2
Low Range/High Range 3 A/30 A 1 A/10 A 6 A/60 A 6 A/60 A 12 A/120 A 3 A/30 A
Low Range Accuracy
3
0.05% + 3 mA 2.5 mA 5 mA 5 mA 10 mA 3 mA
High Range Accuracy
3
0.05% + 6 mA 5 mA 10 mA 10 mA 20 mA 6 mA
Voltage measurement
2
Low Range/High Range 6 V/60 V 24 V/240 V 6 V/60 V 15 V/150 V 6 V/60 V 15 V/150 V
Low Range Accuracy 0.05% + 3 mV 10 mV 3 mV 8 mV 3 mV 8 mV
High Range Accuracy 0.05% + 8 mV 20 mV 8 mV 16 mV 8 mV 16 mV
Power measurement
2
Accuracy 0.1% + 0.5 W 1.2 W 0.5 W 1.5 W 1.2 W 0.5 W
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent dc Electronic Loads maximize throughput with real-life loading conditions