Technical data
73
N3280A Component Test dc Source (Continued)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Application Specific dc Power Supplies tailored solutions for specific needs
Supplemental Characteristics
for all model numbers
dc Floating Voltage: Output terminals can
be floated up to ±50 Vdc maximum from
chassis ground and ±100 Vdc from output
to output.
Remote Sensing: Up to 1/2 the maximum
output voltage may be dropped across
each load lead. Add 1/2 mV to the load
regulation for each 1 V change in the HI
output lead.
Command Processing Time: The time
to set an output parameter is 0.6 ms
for a single output (0.7 ms for all outputs
simultaneously). Time to query a
setting is 1.0 ms (1.5 ms for all outputs
simultaneously)
Dynamic Measurement System
Buffer Size = 4096 points
Sampling rate increments = 30.4 µs
Input Power (full load):
Voltage 100 Vac 120 Vac 220 Vac 230 Vac
Current 1.85 A 1.55 A 0.90 A 0.80 A
(max)
Power 140 W 140 W 140 W 140 W
(max)
Regulatory Compliance: Complies with
EMC directive 89/336/EEC (ISM
group 1 Class A)
Warranty Period: 18 months
Size: 212.7 mm W x 88.9 mm H x
497.8 mm D (8.4 in x 3.5 in x 19.6 in)
See page 105 for more details.
Weight: 10 kg (22 lbs) net; 11.8 kg (26 lbs)
shipping
Ordering Information
Opt 100 87 to 106 Vac, 47 to 63 Hz
Opt 120 104 to 127 Vac, 47 to 63 Hz
Opt 220 191 to 233 Vac, 47 to 63 Hz
Opt 230 207 to 253 Vac, 47 to 63 Hz
Opt 0B0 Delete manual set
Opt 0L1 Standard documentation
package
Opt 0L2 Extra standard
documentation package
Opt 8ZL Add feet – for bench use,
p/n 5041-9167
Opt 1CM Rackmount kit, p/n 5063-9240
Opt AXS Rackmount kit for side-by-side
mounting, Lock-link kit p/n 5061-9694;
Flange Kit p/n 5063-9212; Tie Bracket
Kit p/n 5965-6947
Accessories
p/n N3280A-10001 Virtual Front
Panel Software
Key Literature
Agilent N3280A Component Test
dc Source Datasheet p/n 5988-7080EN