Technical data
The new N3280A dc source offers
semiconductor ATE manufacturers
a reduction in test time, integration
time and rack space. It is a fast,
low-power four-output (±10 V/±0.5 A)
bipolar power supply optimized
for testing RF and mixed signal
semiconductors.
Valuable rack space is saved, by
providing four bipolar outputs that
eliminates the need for four separate
sources and an external polarity
reversal relay.
The N3280A helps maximize test
system throughput with at least
5 times faster performance than any
previous Agilent dc source. It pro-
vides reduced command processing
time both for setting output levels
and for acquiring measurements.
Plus, any combination of outputs
can be grouped in one programming
command, further reducing test time.
Device current consumption can
easily be measured and character-
ized with the digitizing measurement
system. Each output has its own
16-bit precision voltmeter and
ammeter. Additionally, three current
Agilent Application Specific dc Power Supplies tailored solutions for specific needs
Specifications
Applies to each of the four
identical outputs (at 25
˚
±5
˚
C)
Voltage Priority Mode Current Priority Mode
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
71
Save valuable rack space with 4 outputs in a one-half rack box
Increase system throughput with fast command processing time
Accurately measure low level (nA) currents with its 16-bit measurement system
Synchronize measurements to an external event using the trigger system
N3280A
N3280A Component Test dc Source
Number of Outputs 4
GPIB Yes Yes
Output ratings
1
Voltage -10.25 V to +10.25 V -8 V to +8 V (full load)
-11.25 V to +11.25 V (no load)
Current -0.5125 A to +0.5125 A -0.5125 mA to +0.5125 mA
Programming accuracy
at 25
˚
C ±5
˚
C
Voltage 0.1% ±2 mV N/A
+Current 0.1% ±50 µA N/A
-Current limit 0.1% ±50 µA N/A
Current N/A 0.1% ±1 µA
Measurement Accuracy
2
Voltage 0.1% ±2 mV 0.1% ±2 mV
0.5 A current range 0.1% ±200 µA 0.1% ±200 nA
15 mA current range 0.1% ±5 µA 0.1% ±200 nA
0.5 mA current range 0.1% ±200 nA 0.1% ±200 nA
Ripple and noise
from 20 Hz to 20 MHz
Voltage rms 0.380 mV N/A
Peak-to-peak 4 mV N/A
±Current limit rms 40 µA N/A
Current rms N/A 1.5 µA
Load regulation
(A change from no load to full
load or full load to no load by
varying a resistive load)
Voltage ±400 µV N/A
+Current limit ±30 µA N/A
-Current limit ±30 µA N/A
Current N/A ±25 nA
Notes:
1
Full current at 40
˚
C. Linearly derated to 50% of full current at 55
˚
C.
2
Measurement default is 5 measurement samples 30.4 microseconds apart. 0.5 mA range measured with the
number of samples equivalent to one power line cycle.
3