Technical data

This series of 2000 watt dc power
supplies has the exceptional, proven
reliability that test system engineers
look for. It also has the unusual
combination of high efficiency
and low noise operation.
Programming of the dc output and
the extensive protection features
can be done either from the front
panel or using industry standard
SCPI commands, via the GPIB.
Using the serial link, up to 16 power
supplies can be connected through
one GPIB address. Test system
integration can be further simplified
be using the VXIPlug&Play drivers.
The output voltage and current
can also be controlled with analog
signals. This is helpful for certain
types of noisy environments, and
also immediate reactions to process
changes.
Lab-bench use is enhanced by the
fan-speed control, which minimizes
acoustic noise. The extremely low
ripple and noise helps the built-in
measurement system make extreme-
ly accurate current and voltage
measurements.
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Specifications
(at 0
˚
to 55
˚
C unless
otherwise specified)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
39
Proven reliability
Increase test throughput with fast up and down programming
High efficiency
Low ripple and noise
6671A - 6675A
Single-Output: 2000 W GPIB
6671A 6672A 6673A 6674A 6675A
Number of outputs 11111
GPIB Yes Yes Yes Ye s Yes
Output ratings
Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V
Output current 0 to 220 A 0 to 100 A 0 to 60 A 0 to 35 A 0 to 18 A
Programming accuracy
at 25
˚
C ±5
˚
C
Voltage 0.04% + 8 mV 20 mV 35 mV 60 mV 120 mV
Current 0.1% + 125 mA 60 mA 40 mA 25 mA 12 mA
Ripple and noise
from 20 Hz to 20 MHz
Voltage rms 650 µV 750 µV 800 µV 1.25 mV 1.9 mV
Voltage peak to peak 7 mV 9 mV 9 mV 11 mV 16 mV
Current rms 200 mA 100 mA 40 mA 25 mA 12 mA
Readback accuracy at 25˚C ±5˚C
(percent of reading plus fixed)
Voltage 0.05% + 12 mV 30 mV 50 mV 90 mV 180 mV
±Current 0.1% + 150 mA 100 mA 60 mA 35 mA 18 mA
Load regulation
Voltage 0.002%+ 300 µV 650 µV 1.2 mV 2 mV 4 mV
Line regulation
Current 0.005%+ 10 mA 7 mA 4 mA 2 mA 1 mA
Transient response time Less than 900 µs for the output voltage to recover 100 mV following a
change in load from 100% to 50% or 50% to 100% of the output current
rating of the supply
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 2 mV 5 mV 10 mV 15 mV 30 mV
Current 55 mA 25 mA 15 mA 8.75 mA 4.5 mA
OVP 15 mV 35 mV 65 mV 100 mV 215 mV
Output Voltage programming
response time*
(excluding command 30 ms 60 ms 130 ms 130 ms 195 ms
processing time)
*Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output
voltage/rated output current.