Technical data
This series of linear-regulated
80-100 W dc power supplies is
designed to maximize the throughput
of DUTs through the manufacturing
test process. Both programming
and measurement are optimized for
speed. The active downprogrammer
can sink up to the full rated current
of the power supply, which quickly
brings the power supply output to
zero volts. The 6630B Series offers
many advanced programmable
features including stored states
and status reporting. Programming
is done using industry standard
SCPI commands via the GPIB or
RS-232. Test system integration is
further simplified by using the
VXIPlug&Play drivers. The optional
relays simplify system design and
troubleshooting.
The optional front panel binding
posts make the 6630B Series
convenient on the R&D lab bench.
The built-in microamp measurement
system helps the engineer to easily
and accurately monitor the output
voltage and current without a
complicated test setup.
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Specifications
(at 0
˚
to 55
˚
C unless
otherwise specified)
6631B 6632B 6633B 6634B
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
27
Increase production throughput with fast programming speed
Active downprogrammer sinks the full rated current
Protect valuable prototypes with fast protection features
Accurate and fast built-in measurement system
6631B - 6634B
Single-Output: 80-100 W GPIB
Number of outputs 1111
GPIB Yes Yes Yes Yes
Output ratings
Voltage 0 to 8 V 0 to 20 V 0 to 50 V 0 to 100 V
Current 0 to 10 A 0 to 5 A 0 to 2 A 0 to 1 A
Programming accuracy at 25°C ±5°C
Voltage 5 mV 10 mV 20 mV 50 mV
+ Current 0.05% + 4 mA 2 mA 1 mA 0.5 mA
Ripple and noise (20 Hz to 20 MHz, with outputs
ungrounded or with either terminal grounded)
Voltage Normal mode rms 0.3 mV 0.3 mV 0.5 mV 0.5 mV
peak-to-peak 3 mV 3 mV 3 mV 3 mV
Fast mode rms 1 mV 1 mV 1 mV 2 mV
peak-to-peak 10 mV 10 mV 15 mV 25 mV
Current rms 3 mA 2 mA 2 mA 2 mA
dc measurement accuracy via GPIB or front panel
meters with respect to actual output at 25°C ±5°C
Voltage 0.03% + 2 mV 3 mV 6 mV 12 mV
Low current range –20 mA to +20 mA 0.1% + 2.5 µA 2.5 µA 2.5 µA 2.5 µA
High current range +20 mA to + rated I 0.2% + 1 mA 0.5 mA 0.25 mA 0.25 mA
–20 mA to –rated I 0.2% + 1.6 mA 1.1 mA 0.85 mA 0.85 mA
Load regulation
Voltage 2 mV 2 mV 4 mV 5 mV
Current 2 mA 1 mA 1 mA 1 mA
Line regulation
Voltage 0.5 mV 0.5 mV 1 mV 1 mV
Current 1 mA 0.5 mA 0.25 mA 0.25 mA
Transient response time Less than 100 µs (50 µs in the fast mode) for the output voltage to recover to its previous
level (within 0.1% of the voltage rating of the supply or 20 mV) following any step change in load current of up to 50%
of the output current rating of the supply.