Technical data
This series of linear-regulated
40-50 W dc power supplies is
designed to maximize the
throughput of DUTs through the
manufacturing test process with
fast programming and measurement,
and also active downprogramming.
It offers many advanced program-
mable features including stored
states and status reporting. Pro-
gramming is done using industry
standard SCPI commands via the
GPIB or RS-232. Test system
integration is further simplified by
using the VXIPlug&Play drivers.
The optional relays simplify system
design and troubleshooting.
The half-rack size of the 6610A
series makes it a convenient
dc power supply for the R&D lab
bench. The built-in microamp
measurement system helps the
engineer to easily and accurately
monitor the output voltage and
current without a complicated
test setup.
Agilent Performance dc Power Supplies speed and accuracy for test optimization
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
25
Increase production throughput with fast programming speed
and fast downprogramming time
Protect valuable prototypes with fast protection features
Accurate and fast built-in measurement system
6611C - 6614C
Single-Output: 40-50 W GPIB
Specifications
(at 0
˚
to 55
˚
C unless
otherwise specified)
6611C 6612C 6613C 6614C 6611C-
J05
Special Order
Option
Number of outputs 11111
GPIB Yes Yes Yes Yes Yes
Output Ratings
Voltage 0 to 8 V 0 to 20 V 0 to 50 V 0 to 100 V 0 to 10 V
Current 0 to 5 A 0 to 2 A 0 to 1 A 0 to 0.5 A 0 to 5 A
Programming accuracy (at 25°C ±5°C)
Voltage 5 m V 10 m V 20 m V 50 m V 5 m V
+Current 0.05% + 2 m A 1 m A 0.75 m A 0.5 m A 2 m A
Ripple and noise 20 Hz to 20 MHz, with outputs
ungrounded or with either terminal grounded
Voltage rms 0.5 mV 0.5 mV 0.5 mV 0.5 mV 0.5 mV
peak -to-peak 3 mV 3 mV 4 mV 5 mV 3 mV
Normal mode rms 2 mA 1 mA 1 mA 1 mA 2 mA
dc measurement accuracy via GPIB or front-panel
meters respect to actual outputat 25°C ±5°C
Voltage 0.03% + 2 mV 3 mV 6 mV 12 mV 2 mV
Low current range -20 mA to + 20 mA 0.1% + 2.5 µA 2.5 µA 2.5 µA 2.5 µA 2.5 µA
High current range +20 mA to + rated 1 0.2% + 0.5 mA 0.25 mA 0.2 mA 0.1 mA 0.5 mA
-20 mA to - rated 1 0.2% + 1.1 mA 0.85 mA 0.8 mA 0.7 mA 1.1 mA
Load regulation
Voltage 2 mV 2 mV 4 mV 5 mV 2 mV
Current 1 mA 0.5 mA 0.5 mA 0.5 mA 1 mA
Line regulation
Voltage 0.5 mV 0.5 mV 1 mV 1 mV 0.5 mV
Current 0.5 mA 0.5 mA 0.25 mA 0.25 mA 0.5 mA
Transient response time Less than 100 µs for the output to recover to its previous level (within 0.1% of the voltage
rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of the
output current rating of the supply
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average programming resolution
Voltage 2 mV 5 mV 12.5 mV 25 mV 3 mV
Current 1.25 mA 0.5 mA 0.25 mA 0.125 mA 1.25 mA
Sink current 3 A 1.2 A 0.6 A 0.3 A 3 A