Technical data
23
Supplemental Characteristics
for all model numbers
dc Floating Voltage: Output terminals can
be floated up to ±240 Vdc from chassis
ground
Remote Sensing: Up to 1 V can be dropped
in each load lead. The drop in the load
leads subtracts from the voltage available
for the load.
Settling Time: Less than 90msec for the
output voltage to change from 1% to 99%
or vice versa following the receipt of
VOLTage or APPLy command via direct
GPIB or RS-232 interface.
Product Regulation:
Designed to comply with UL3111-1;
certified to CSA 22.2 No. 1010.1; conforms
to IEC 1010-1; complies with EMC
directive 89/336/EEC(Group1, Class A)
OVP Accuracy: 0.5% + 0.5 V, activation
time: ≥3 V, <1.5 ms, and <3 V, <10 ms
Isolation: ±240 Vdc
Stability: Voltage <0.02% + 2 mV;
Current <0.1% + 1 mA
Temperature Coefficient: <0.01% + 3 mV,
<0.02% + 3 mA change per
˚
C
over operating range 0-40
˚
C
after 30 minute warm-up
Warranty Period: Three years
Size: (E3640A-E3645A)
254.4 mm W x 104 mm H x 374 mm D
(10 in. x 4.1 in. x 14.8 in.)
(E3646A-E3649A)
213 mm W x 133 mm H x 348 mm D
(8.4 in. x 5.2 in. x 13.7 in.)
Weight: E3640A, E3641A: 5.3 kg (11.7 lbs)
E3642A, E3643A: 6.2 kg (13.7 lbs)
E3644A, E3645A: 6 kg (13.2 lbs)
E3646A, E3647A: 7.4 kg (16.3 lbs)
E3648A, E3649A: 9.5 kg (20.9 lbs)
Single & Dual Output: 30-100 W GPIB (Continued)
Specifications
(at 0
˚
to 55
˚
C unless
otherwise specified)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Basic dc Power Supplies essential features for a tight budget
E3645A E3646A E3647A E3648A E3649A
Number of outputs 12222
GPIB Yes Yes Yes Yes Yes
dc outputs
Voltage 0 to 35 V 0 to 8 V 0 to 35 V 0 to 8 V 0 to 35 V
Current 2.2 A 3 A 0.8 A 5 A 1.4 A
Voltage 0 to 60 V 0 to 20 V 0 to 60 V 0 to 20 V 0 to 60 V
Current 1.3 A 1.5 A 0.5 A 2.5 A 0.8 A
Power (max) 80 W 60 W 60 W 100 W 100 W
Load and line regulation
Voltage <0.01% + 3 mV 3 mV 3 mV 3 mV 3 mV
Current <0.01% + 250 µA 250 µA 250 µA 250 µA 250 µA
Ripple and noise
from 20 Hz to 20 MHz
Normal-Mode Voltage <1 mVrms <500 µVrms <1 mVrms <500 µVrms <1 mVrms
8 mVp-p 5 mVp-p 8 mVp-p 5 mVp-p 8 mVp-p
Normal-Mode Current <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms
Common-Mode Current <1.5 µArms <1.5 µArms <1.5 µArms <1.5 µArms <1.5 µArms
Programming accuracy
at 25
˚
C ±5
˚
C
Voltage <0.05% + 10 mV 10 mV 10 mV 10 mV 10 mV
(<0.1% + 25 mA for output 2)
Current <0.2% + 10 mA 10 mA 10 mA 10 mA 10 mA
Readback accuracy at 25˚C ±5˚C
Voltage <0.05% + 5 mV 5 mV 5 mV 5 mV 5 mV
(<0.1% + 25 mV for output 2)
Current <0.15% + 5 mA 5 mA 5 mA 5 mA 5 mA
(<0.15% + 10 mA for output 2)
Program resolution
Voltage 5 mV 5 mV 5 mV 5 mV 5 mV
Current 1 mA 1 mA 1 mA 1 mA 1 mA
Readback resolution
Voltage 2 mV 2 mV 2 mV 2 mV 2 mV
Current 1 mA 1 mA 1 mA 1 mA 1 mA
Meter resolution
Voltage 10 mV 10 mV 10 mV 10 mV 10 mV
Current 1 mA 1 mA 1 mA 1 mA 1 mA
Transient response <50 µsec for output to recover to within 15 mV following a change in
output current from full load to half load or vice versa.
*Maximum current is derated 1% per °C from 40°C to 55°C
Ordering Information
Opt 0E3 207 to 253 Vac, 47 to 63 Hz
Opt 0E9 90 to 110 Vac,
47 to 63 Hz (Japan only)
Opt 0EM 104 to 126 Vac, 47 to 63 Hz
Opt 1CM Rack mount kit
(E3640A-E3645A p/n5063-9240;
E3646A-E3649A p/n 5063-9243)
Opt 0L2 Extra documentation package
Opt 0B0 Delete documentation