Table 3C - Terminated Line Cords (Line cords with plugs)
Option Description
Number
Option 841 12 AWG, 3 wire; UL-Listed, CSA-certified; NEMA 6-20P, 20-A,
250-V plug; 8 ft. Use for connection to 200-240 Vac mains.
Note for 657XA or 667XA series, E4356A and 6813B: not
acceptable for use in Canada or Japan. Choose either -834 or
-844 10 AWG power cord option.
Option 842 4-mm
2
wire size; harmonized cordage with IEC 309, 32-A,
220-V plug. Suggested for use in Europe and other areas not listed.
Option 844 10 AWG, 3 wire; UL-Listed, CSA-certified; with NEMA L6-30P, 30-A,
250-V locking plug; 8 ft. Suggested for use in North and South
America. Note for 657XA or 667XA series, E4356A and 6813B: not
acceptable for use in Canada or Japan. Choose either -834 or
-844 10 AWG power cord option.
Option 845 1.5-mm
2
wire size; harmonized cordage with IEC 309, 16-A,
220-V plug. Suggested for use in Denmark, Switzerland, Austria,
China and other countries not listed.
Option 846 10 AWG, 3 wire; UL-Listed, CSA-certified; with NEMA L5-30P,
30-A, 120-V locking plug; 8 ft. Suggested for use in North America.
Note for 601XA or 603XA series, 66000A or 6812B: required for
connection to 100-120 Vac mains.
Option 847 1.5-mm
2
wire size; harmonized cordage with CEE 7/7, 16-A,
220-V plug. Suggested for use in continental Europe.
Option 848 1.5-mm
2
wire size; harmonized cordage with BS 546, 15-A, 240-V
plug. Suggested for use in India and South Africa.
All Agilent 3-phase power products
are shipped with either a North
American or harmonized untermi-
nated line cord based on the
destination country on the
purchase order.
Table 4 - Three Phase ac Input Systems
668XA and 669XA Delta Wye
Standard 180-235 volts 180-235 volts 104-136 volts
180-235 volts (line-to-line) (line-to-line) (line-to-line) (line-to-neutral)*
Option 400 360-440 volts 360-440 volts 208-254 volts
360-440 volts (line-to-line) (line-to-line) (line-to-line) (line-to-neutral)*
*Note: Never connect to the Neutral line connection when powering an Agilent 3
Product. Included as
information ONLY. Standard: p/n 8120 -6203 Opt 400: p/n 8120 -6204
For information on single-phase operation, see page 107 question 2.
These are the ONLY
connections used
when powering the
668XA and 669XA
Earth Gnd
V
(line-to-neutral)
Neutral
(never used)
V
(line-to-line)
V
(line-to-line)
OC
OB
OA
Delta