Specifications

136
Chapter 5: Troubleshooting
5 Set up the Listing window.
a In the Analyzer Setup window, select Window, then select Slot n:
Analyzer (where ā€œnā€ is the slot the module under test is installed), then
select Listing. A Listing window opens.
b Right click on the Hex field and change the Lab1 base to Binary.
6 Using four 6-by-2 test connectors, connect the logic analyzer to the pulse
generator channel outputs. To make the test connectors, see chapter 3,
"Testing Performance."
a Connect the even-numbered channels of the lower byte of the pod
under test to the pulse generator channel 1 Output.
b Connect the odd-numbered channels of the lower byte of the pod under
test to the pulse generator channel 1 Output
.
c Connect the even-numbered channels of the upper byte of the pod
under test and the J clock channel to the pulse generator channel 2
Output. J clock is located on Pod 1.
d Connect the odd-numbered channels of the upper byte of the pod
under test to the pulse generator channel 2 Output.