Specifications
Chapter 16 273
Command Reference
:DISP:TEXT1:CALC{11-12}:FIX
16. Command Reference
:DISP:TEXT1:CALC{11-12}:FIX
Syntax :DISPlay[:WINDow]:TEXT1:CALCulate{11|12}:FIX {ON|OFF|1|0}
:DISPlay[:WINDow]:TEXT1:CALCulate{11|12}:FIX?
Description Specifies whether to fix the decimal point in the screen display of the results of monitoring
the test signal current level (:CALC11) or voltage level (:CALC12).
Parameters
Query response {1|0}<newline><^END>
Equivalent key
sequence
[Display] - SETUP MEAS DISP - {I-mon|V-mon} - MSD FIXED
:DISP:TEXT1:CALC{11-12}:MSD
Syntax :DISPlay[:WINDow]:TEXT1:CALCulate{11|12}:MSD <numeric>
:DISPlay[:WINDow]:TEXT1:CALCulate{11|12}:MSD?
Description When the instrument is configured to fix the decimal point in the screen display of the
results of monitoring the test signal current level (:CALC11) or voltage level (:CALC12),
use this command to set the most significant digit. You can specify the most significant
digit by its exponent. For example, to set the most significant digit to 0.01 (1E-2), specify
-2 as the parameter value.
Parameters
If your specified parameter is beyond the valid range, the instrument ignores the parameter
and uses either the maximum or minimum value depending on whether the parameter is
greater than the upper limit or smaller than the lower limit.
Query response {numeric}<newline><^END>
Equivalent key
sequence
[Display] - SETUP MEAS DISP - {I-mon|V-mon} - MODIFY MSD
Description
ON or 1 Instructs instrument to fix the decimal point
OFF or 0 (initial value) Instructs instrument NOT to fix the decimal point
<numeric>
Description Exponent that indicates the most significant digit
Range -15 to 15
Default 0
Resolution 1