Technical data
134 4000 X-Series Oscilloscopes Advanced Training Guide
4 Serial Bus Decoding & Triggering, Search & Navigation, and Segmented Acquisition Labs
Note that your scope should still be triggering on random edge crossings of
channel- 1. Let's now set up the scope to a specific trigger point - when it
detects an IN token packet.
17 Press the [Trigger] front panel key; then select Serial 1 (USB).
18 Tap the Trigger on: softkey; then select Token Packet.
19 Tap the PID softkey, and select IN as the token we want to trigger on.
You should now see stable waveform traces on your scope's display similar
to Figure 91. Of course, there is still a bit of confusion as it is triggering
on multiple IN packets, which are rapidly flashing on the bottom of the
screen in the blue decode area. Let's zoom out and see the scope's ability
to list all decoded traffic, to discover a unique and stable trigger point.
Figure 90 Fast, hardware decoding of USB traffic.