User`s guide

SDFTOBIN
Convert the source SDF file to the destination binary file. The binary data has the bytes swapped in the
same direction as the rest of the DOS environment.
Syntax SDFTOBIN<sfile><dfile>[/U][/O][/I][/A][/X][/T:<c1>,<c2>][/Y:<units>]
[/M:<dBmRef>] [/G:<dBRef>] [/D:<data>] [/R:<row>] [/C:<col>] [/S[:<scan>[
<scanEnd>]]] [/F:<format>]
Options
<sfile> Input SDF file.
<dfile> Output binary file.
/U Show this usage.
/O Overwrite <dfile> if it exists.
/I Info only on <sfile> (that is, measurement results available).
/A All frequency lines.
/X Include X data in the file.
/T:<c1>,<c2> Y coordinate, <c1> or <c2> may be one of the following:
B=dBm
D=dB
S=dB signed
M=Mag
R=Real
I=Imag
P=Phase
U=Unwrap phase
Default is R,I for complex data; R for real data.
/Y:<units> Y units, one or more of the following:
L=Linear,
P=Power,
D=Density,
R=RMS,
A=Radians
/M:<dBmRef>] dBm impedance reference. Default is use input impedance from the data file if 1
MOhm (else use 50 Ohm).
Sharing Data Between Analyzers
SDFTOBIN
4-42