User`s guide
28
General specifications
Powersupply Universal100Vto240V±10%
Powerlinefrequency 50–60Hz±10%automaticallysensed
Power consumption 150 VA
Operating environment Full accuracy for 0 °C to 55 °C
Fullaccuracyto80%R.H.at40°C
IEC 60664-1 pollution degree 1
Storageenvironment -40°Cto70°C
[1]
Mainframe dimensions 133 H x 426 W x 341 D mm (5.25” x 16.8” x 14”)
Full rack, 3 units high
Mainframe weight 8.8 kg (19.6 lbs)
Moduledimensions 280Hx170Wx27Dmm(11”x6.7”x1”)
Moduleweights 0.73to1.18kg(1.6to2.6lbs)
Terminalblockdimensions 28Hx170Wx114Dmm(1.1”x6.7”x4.5”)
Terminalblockweights 0.27to0.36kg(0.6to0.8lbs)
Safetyconformsto CSA,UL/IEC/EN61010-1
EMCconformsto IEC/EN61326-1,CISPR11
Warranty 1 year
Software
Agilent connectivity software included
AgilentIOLibrariesSuite14orgreater(E2094)
Minimum system requirements (IO libraries and drivers)
PChardware IntelPentium100MHz,64MbyteRAM,
210 Mbyte disk space
Display800x600,256colors,CD-Romdrive
Operating system
[2]
Windows
®
98SE/NT/2000/XP
Computer interfaces StandardLAN10BaseT/100BaseTx
StandardUSB2.0
IEEE488.2GPIB
Software driver support for programming languages
Softwaredrivers: IVI-CandIVICOMforWindowsNT/2000/XP
LabVIEW
Compatible with programming tools and environments:
AgilentVEEPro,AgilentT&MToolkit
(requiresVisualStudio.NET)
NationalInstrumentsTestStand,
MeasurementStudio,LabWindows/CVI,
LabVIEW,SwitchExecutive
MicrosoftVisualStudio.NET,C/C++,
VisualBasic6
Agilent BenchLink data logger software system requirements
Operating system: Windows 2000 SP4, XP SP 2
Controller: RecommendPentium
®
4, 800 MHz or
greater, Min: Pentium III, 500 MHz
RAM: Recommend256MBorgreater,Min128MB
DiskSpace: Recommend200MB,Min100MB
Display: 1024x768resolution,256colors
Agilent BenchLink data logger features
Configuration Spreadsheet-like channel configurations page.
Upload and Download instrument configura-
tions.Computedchannelsusing+-*/,dB,
dBm,dBV,x2,xandfull,
1
/
2
, or
1
/
4
bridge strain
GraphicalDisplays Real-timeandhistoricaldatadisplaysAdd,
delete, size, and configure real time Strip chart
with markers and alarm indication, bar and
scattercharts,Histogramwithstatistics,Bar
meter, and Data table
GraphicalControls Sliders,switches,buttons,andLEDlights
Alarm/Limittesting Start/Stopscanningonalarmcondition
Control34903Arelaystateor34907Adigital
output on alarm
Data Realtimestreamed(saved)todisk
Automatically export data and configurations
Copy data or graphics to windows clipboard
Exportyourselecteddatato.CVS,.XML,orTXT
formats
Event logging Automatic entry of alarms and errors
[1] Storage at temperatures above 40 °C will decrease battery life
[2] LoadIOLibrariesVersionMforWindowsNTsupportorversion
14.0 for Windows 98 SE support
Definitions for specifications
Specifications describe the warranted performance of calibrated
instruments that have been stored for a minimum of 2 hours within
the operating temperature range of 0 °C to 50 °C, unless otherwise
stated, and after a 45 minute warm-up period. Data represented in
this document are specifications unless otherwise noted.
Characteristics describe product performance that is useful in the
application of the product, but that is not covered by the prod-
uct warranty. Characteristics are often referred to as Typical or
Nominal values.
• Typical describes characteristic performance, which 80% of
instruments will meet when operated over a 20 °C to 30 °C tem
perature range. Typical performance is not warranted.
• Nominal describes representative performance that is useful in
the application of the product when operated over a 20 °C to
30 °C temperature range. Nominal performance is not warranted.
Note: All graphs contain measured data from several units at room
temperature unless otherwise noted.