System information

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 7-5
Chapter 7: Additional Information for Networking
The Private LAN This section contains:
3070 Private LAN IP Addresses, 7-5
3070 Private LAN IP Addresses
Your 3070 MS Windows system includes two network
adapter cards for connecting to local area networks.
(LANs). The first network adapter card is configured
and reserved for the private LAN. It is represented as
Local Area Connection in Network and Dial-up
Connections. Local Area Connection communicates
directly from the controller to the testhead. Do not
change these settings. There should not be other devices
attached to this LAN other than shown in Figure 7-1 on
page 7-6.
The private LAN IP addresses are standard for every
test system.Table 7-1 shows the IP addresses reserved
for the 3070 private LAN.
Table 7-1 3070 Private LAN IP Addresses
IP Address Address Reserved for:
10.3.112.10
The 3070 MS Windows controller. (Local Area Network)
10.3.112.2
The testhead system card.
10.3.112.4
Module 0 of the ControlXT card.
10.3.112.5
Module 1 of the ControlXT card.
10.3.112.6
Module 2 of the ControlXT card.
10.3.112.7
Module 3 of the ControlXT card