System information
© Agilent Technologies 2001–2003 Administering Agilent 3070 Systems (MS Windows NT and 2000) 4-29
Chapter 4: Backing Up and Restoring System Software
System Recovery Procedure
6 Load the System Recovery DVD in your DVD-ROM
drive.
7 Restart the computer. If necessary, press the reset
button on the front of the computer.
8 At the Agilent 3070: prompt, type restore system.
9 Press any key to scroll through the license
agreement.
10 In the Power Quest screen, click Continue.
11 In the Warning message window, click Yes.
12 When the restoration is completed and you see the
Agilent 3070: prompt, remove the DVD from the
drive.
13 Press CTRL-ALT-DEL to restart the computer.
IO Configuration Procedure
1 Log in as administrator.
2 Right-click the blue IO icon on the right side of the
Taskbar and select Run IO Config.
3 In the Available Interface Types field, select 82350 PCI
GPIB (older controllers) or 82357 USB to GPIB (newer
controllers) and click Configure.
4 In the SICL Interface Name field, ensure that hpib7 is
selected, and click OK.
5 In the IO Config window, click OK.
6 In the Restart message window, click OK.
7 Restart the computer: click Start > Shutdown > select
Restart > click OK.
This concludes the recovery procedure. Now restore the
unique files listed on page 28.