System information

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-47
Chapter 8: Reference
DUT Power
Supplies
Voltage Ranges
DUT power supplies are set at the factory to one of two
configurations:
Option 220 for line voltages of 200–220 volts.
Option 240 for line voltages of 230–240 volts.
DUT Power Supplies Allowed
See Table 8-16 for the DUT power supplies allowed.
Module Mappings
See Table 8-17 for default DUT power supply mappings
for each module.
Table 8-16 DUT power supplies allowed
Product No. Model No. Description
44940A 6624A 4 outputs: 2 @ 0-7 V, 0-5 A or 0-20 V, 0-2 A and 2 @ 0-20 V, 0-2 A or 0-50 V, 0-0.8 A
44941A 6621A 2 outputs: 0-7 V, 0-10 A and 0-20 V, 0-4 A
E4034A 6634A 1 output: 1-100 V, 0-1 A
E3784A 6642A 1 output: 0-20 V, 0-10 A
Table 8-17 Default DUT power supply mappings for each module (rear view of testhead)
Module 0 Module 2
supplies hp6624 13 to 16 asru channels 1 to 4 ! supplies hp6624 5 to 8 asru channels 1 to 4
! supplies hp6621 13 to 14 asru channels 1 to 4 supplies hp6621 5 to 6 asru channels 1 to 4