System information

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-45
Chapter 8: Reference
H_StdDD2 hybrid standard double density 6 E4000-66550
H_PpuDD hybrid standard double density 6 E4000-66546
HPpuDD2 hybrid standard double density 6 E4000-66550
H_AdvDD hybrid advanced double density 12 E4000-66544
HAdvDD2 hybrid advanced double density 12 E4000-66550
H_HA_DD hybrid high accuracy double
density
20 E4000-66545
HHADD2 hybrid high accuracy double
density
20 E4000-66550
HStd_32 hybrid standard double density 32 6 E9900-66502
HAdv_32 hybrid advanced double density 32 12 E9900-66502
H_HA_32 hybrid high accuracy double
density 32
20 E9900-66502
HPpu_32 hybrid high accuracy double
density 32
20 E9900-66502
CAUTION
If a serial keyword exists in the system config. file, then serial ports statements MUST be defined
in the standard config file /var/hp3070/diagnostics/th1/config for each STC Plus Card. Also the
serial test codeword MUST be in the /var/hp3070/bin/.enable file.
Table 8-15 For MS Windows systems – supported testhead cards with diagnostics names, cards <keywords> statements,
pattern applications rates and part numbers (continued)