System information

© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-37
Chapter 8: Reference
5 If a ControlXT Card was removed, delete its
hardware address:
a Pull down the Hardware Address menu and
select the address of the card you removed.
b Click Delete.
6 Add the hardware address of the ControlXT Card
you are installing:
a Click New.
b Enter the hardware address of the ControlXT
Card. The complete hardware address is typically
0060B0B2xxxx (xxxx = the number on the card).
7 Configure the card’s address:
a In the Available options menu, select the following
three options one at a time and click >> to move
them to the Configured options menu:
IP address >>
Merit dump file >>
Subnet mask >>
b In the Configured options menu, select each option
and click Edit.
Enter:
IP Address = 10.3.112.4 for module 0
10.3.112.5 for module 1
10.3.112.6 for module 2
10.3.112.7 for module 3
Merit dump file = This is a comment; enter
the module number (e.g., module 2).
Subnet mask = 255.255.255.0
8 In the BOOTP Server properties window, click Close.
9 Restart the BOOTP Server:
a From Control Panel click Administrative Tools,
then Services.
b Double-click Weird Solutions BOOTP Server.
c Click Stop > Start (wait).
10 Close the Services and Administrative Tools
windows.
This completes the procedure.
IP Addresses
The bootptab file, in conjunction with the hosts file,
manages IP addresses for the modules in the testhead.
See The hosts File on page 8-38 to view IP addresses
for the testhead modules.