Specifications

10 Release Notes
CR34177 08.20p: R1314 NPM testname.bd file is incorrect.
CR34180 08.20p: Wrong error message for ASRU calibration.
CR34181 08.00p: Pushbutton Debug window closes when marking a test as permanent.
CR34186 07.20p: Fix locations of Module 0 and 1 shown in online help.
CR34191 08.20p: Coverage Analyst does not handle preshorts and powered analog tests correctly.
CR34192 08.20p: NIST Calibration testplan uses wrong temperature unit in report header.
CR34200 08.20p: BT-Basic gives Internal Error -13 at “Select boards on panel”.
CR34204 08.00p: UnMux card relay locator diagram shows incorrect references designators.
CR34209 08.20p: BSDL parser does not flag single-ended, differential pins as error.
CR34216 08.20p: BSDL compiler does not warn or error out if multiple drivers are connected to a single
signal.
CR34227 08.20p: Board Consultant should display more than five heterogeneous boards.
CR34228 08.20p: Board setting allows IPG to write AC or DC mode capacitor test.
CR34229 08.20p: Enhancement – Make FXT53 WARNING message (for insufficient access) more
obvious.
CR34231 08.20p: Setup Editor could not be launched.
CR34236 08.20p: Conversion Tool needs updating for 8.x software.
CR34239 08.10p: Improve file checking efficiency over network.
CR34240 08.00p: DGN reports 3374/3376 errors with ASRU-N card.
CR34248 08.20p: Testplan statements
itb$ and num cause missing characters in the output display and
in datalogging.
CR34249 08.20p: Pushbutton Debug does not display line numbers and calling sequence for mixed test.
CR34252 08.00p: IPG fails to assign mux power supply wiring for Utility Card.
CR34258 08.10p: ConnectCheck learned value not saved in Pushbutton Debug.
CR34263 08.20p: Actel STAPL not compatible with PLD ISP.
CR34265 08.20p: Extra line “sequencer halted” in digital failure message.
CR34268 08.20p: IPG selects inaccessible nodes in .discharge test.
CR34269 08.20p: ICT Browser and Engineer Test Interface show “Error in File Type: board”.
CR34270 08.20p: Breaking recycles to fail for Polarity test causes Pascal system error 8.
Table 6
Change
Request
Identification
Description