Oscilloscope Utility Settings 6
Agilent 3000 Series Oscilloscopes User’s Guide 113
To turn on/off the mask test message display
1 In the Mask Test menu (Utility→Mask Test), select Msg Display to toggle
between OFF and ON.
The message display shows the failed, passed, and total number of
waveforms.
To set the mask test output condition
1 In the Mask Test menu (Utility→Mask Test), select Output.
2 Continue pressing the menu button to select the desired output
condition:
• Fail — A mask failure sets the output.
• Pass — A passing waveform sets the output.
The output condition can be used to stop a running mask test or as a
source for the waveform recording function (see “Recording/Playing- back
Waveforms” on page 83).
To stop a mask test on the output condition
To turn on/off stopping the mask test when the output condition occurs:
1 In the Mask Test menu (Utility
→Mask Test), select Stop On Output to toggle
between OFF and ON.