Saving, Recalling, and Printing Data 5
Agilent 3000 Series Oscilloscopes User’s Guide 105
For information on using the Save menu, see “To save a file to a USB
device” on page 106.
For information on using the Load menu, see “To load a file from a
USB device” on page 108.
To save/load oscilloscope setups to/from a USB device
You can save/load setups to an external USB drive when it is connected to
the USB host port.
1 Press Save/Recall
.
2 In the Save/Recall menu, press Storage until “USB” is selected.
3 Press File Type until “Setup” is selected.
4 Press Save or Load.
For information on using the Save menu, see “To save a file to a USB
device” on page 106.
For information on using the Load menu, see “To load a file from a
USB device” on page 108.
To save screens to BMP format files (on a USB device)
You can save oscilloscope display screens (in BMP format) to an external
USB drive when it is connected to the USB host port.
1 Press Save/Recall
.
2 In the Save/Recall menu, press Storage until “USB” is selected.
3 Press File Type until “Bit map” is selected.
4 Press Bmp Format to select between 24- bit and 8- bit.
5 Press Save.
For information on using the Save menu, see “To save a file to a USB