Technical data

Commands Quick Reference 4
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide 75
Table 8 :DEMO Commands Summary
Command Query Options and Query Returns
:DEMO:FUNCtion
<signal> (see
page 238)
:DEMO:FUNCtion? (see
page 239)
<signal> ::= {SINusoid | NOISy |
PHASe | RINGing | SINGle | AM |
CLK | GLITch | BURSt | MSO |
RFBurst | LFSine | FMBurst}
:DEMO:FUNCtion:PHASe:
PHASe <angle> (see
page 240)
:DEMO:FUNCtion:PHASe:
PHASe? (see page 240)
<angle> ::= angle in degrees from
0 to 360 in NR3 format
:DEMO:OUTPut {{0 |
OFF} | {1 | ON}} (see
page 241)
:DEMO:OUTPut? (see
page 241)
{0 | 1}
Table 9 :DIGital<d> Commands Summary
Command Query Options and Query Returns
:DIGital<d>:DISPlay
{{0 | OFF} | {1 |
ON}} (see page 245)
:DIGital<d>:DISPlay?
(see page 245)
<d> ::= 0 to (# digital channels
- 1) in NR1 format
{0 | 1}
:DIGital<d>:LABel
<string> (see
page 246)
:DIGital<d>:LABel?
(see page 246)
<d> ::= 0 to (# digital channels
- 1) in NR1 format
<string> ::= any series of 10 or
less ASCII characters enclosed in
quotation marks
:DIGital<d>:POSition
<position> (see
page 247)
:DIGital<d>:POSition?
(see page 247)
<d> ::= 0 to (# digital channels
- 1) in NR1 format
<position> ::= 0-7 if display
size = large, 0-15 if size =
medium, 0-31 if size = small
Returns -1 when there is no space
to display the digital waveform.
:DIGital<d>:SIZE
<value> (see
page 248)
:DIGital<d>:SIZE?
(see page 248)
<d> ::= 0 to (# digital channels
- 1) in NR1 format
<value> ::= {SMALl | MEDium |
LARGe}
:DIGital<d>:THReshold
<value>[suffix] (see
page 249)
:DIGital<d>:THReshold
? (see page 249)
<d> ::= 0 to (# digital channels
- 1) in NR1 format
<value> ::= {CMOS | ECL | TTL |
<user defined value>}
<user defined value> ::= value in
NR3 format from -8.00 to +8.00