Technical data

Obsolete and Discontinued Commands 33
Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide 715
:DISPlay:ORDer
(see page 790)
Query Syntax
:DISPlay:ORDer?
The :DISPlay:ORDer? query returns a list of digital channel numbers in
screen order, from top to bottom, separated by commas. Busing is
displayed as digital channels with no separator. For example, in the
following list, the bus consists of digital channels 4 and 5: DIG1, DIG4
DIG5, DIG7.
Return Format
<order><NL>
<order> ::= Unquoted ASCII string
See Also ":DIGital<d>:POSition" on page 247
Example Code
' DISP_ORDER - Set the order the channels are displayed on the
' analyzer. You can enter between 1 and 32 channels at one time.
' If you leave out channels, they will not be displayed.
' Display ONLY channel 0 and channel 10 in that order.
myScope.WriteString ":DISPLAY:ORDER 0,10"
See complete example programs at: Chapter 38, “Programming Examples,”
starting on page 799
NOTE
The :DISPlay:ORDer command is an obsolete command provided for compatibility to
previous oscilloscopes. This command is only available on the MSO models.
NOTE
A return value is included for each digital channel. A return value of NONE indicates that a
channel is turned off.