Technical data
706 Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
33 Obsolete and Discontinued Commands
Discontinued
Commands
Discontinued commands are commands that were used by previous
oscilloscopes, but are not supported by the InfiniiVision 2000 X- Series
oscilloscopes. Listed below are the Discontinued commands and the
nearest equivalent command available (if any).
:TIMebase:DELay (see
page 748)
:TIMebase:POSition (see
page 580) or
:TIMebase:WINDow:POSition
(see page 585)
TIMebase:POSition is position
value of main time base;
TIMebase:WINDow:POSition
is position value of zoomed
(delayed) time base window.
:TRIGger:THReshold (see
page 749)
:POD<n>:THReshold (see
page 414) or
:DIGital<d>:THReshold (see
page 249)
:TRIGger:TV:TVMode (see
page 750)
:TRIGger:TV:MODE (see
page 623)
Obsolete Command Current Command Equivalent Behavior Differences
Discontinued Command Current Command Equivalent Comments
ASTore :DISPlay:PERSistence INFinite
(see page 261)
CHANnel:MATH :FUNCtion:OPERation (see
page 289)
ADD not included
CHANnel<n>:PROTect :CHANnel<n>:PROTection
(see page 232)
Previous form of this
command was used to
enable/disable 50Ω
protection. The new command
resets a tripped protect and
the query returns the status of
TRIPed or NORMal.
DISPlay:INVerse none
DISPlay:COLumn none
DISPlay:FREeze none
DISPlay:GRID none
DISPLay:LINE none
DISPlay:PIXel none
DISPlay:POSition none
DISPlay:ROW none
DISPlay:TEXT none
FUNCtion:MOVE none