Technical data

676 Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
31 :WGEN Commands
:WGEN:MODulation:FSKey:FREQuency
(see page 790)
Command Syntax
:WGEN:MODulation:FSKey:FREQuency <frequency>
<frequency> ::= hop frequency in Hz in NR3 format
The :WGEN:MODulation:FSKey:FREQuency command specifies the "hop
frequency".
The output frequency "shifts" between the original carrier frequency and
this "hop frequency".
Query Syntax
:WGEN:MODulation:FSKey:FREQuency?
The :WGEN:MODulation:FSKey:FREQuency? query returns the "hop
frequency" setting.
Return Format
<frequency><NL>
<frequency> ::= hop frequency in Hz in NR3 format
See Also ":WGEN:MODulation:AM:DEPTh" on page 672
":WGEN:MODulation:AM:FREQuency" on page 673
":WGEN:MODulation:FM:DEViation" on page 674
":WGEN:MODulation:FM:FREQuency" on page 675
":WGEN:MODulation:FSKey:RATE" on page 677
":WGEN:MODulation:FUNCtion" on page 678
":WGEN:MODulation:FUNCtion:RAMP:SYMMetry" on page 679
":WGEN:MODulation:STATe" on page 681
":WGEN:MODulation:TYPE" on page 682