Technical data
618 Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
29 :TRIGger Commands
You can only specify an edge on one channel. When an edge is specified,
the :TRIGger:PATTern:QUALifier does not apply.
Query Syntax
:TRIGger:PATTern?
The :TRIGger:PATTern? query returns the pattern string, edge source, and
edge.
Return Format
<string>,<edge_source>,<edge><NL>
See Also • "Introduction to :TRIGger Commands" on page 589
• ":TRIGger:PATTern:FORMat" on page 619
• ":TRIGger:PATTern:QUALifier" on page 620
• ":TRIGger:MODE" on page 598
NOTE
The optional <edge_source> and <edge> parameters should be sent together or not at all.
The edge can be specified in the ASCII <string> parameter. If the edge source and edge
parameters are used, they take precedence.