Technical data
412 Agilent InfiniiVision 2000 X-Series Oscilloscopes Programmer's Guide
22 :POD Commands
:POD<n>:DISPlay
(see page 790)
Command Syntax
:POD<n>:DISPlay <display>
<display> ::= {{1 | ON} | {0 | OFF}}
<n> ::= An integer, 1, is attached as a suffix to the command and
defines the group of channels that are affected by the command.
POD1 ::= D0-D7
The :POD<n>:DISPlay command turns displaying of the specified group of
channels on or off.
Query Syntax
:POD<n>:DISPlay?
The :POD<n>:DISPlay? query returns the current display setting of the
specified group of channels.
Return Format
<display><NL>
<display> ::= {0 | 1}
See Also • "Introduction to :POD<n> Commands" on page 411
• ":DIGital<d>:DISPlay" on page 245
• ":CHANnel<n>:DISPlay" on page 222
• ":VIEW" on page 182
• ":BLANk" on page 158
• ":STATus" on page 179
NOTE
This command is only valid for the MSO models.