Specifications
15
Pattern Generator Specifications and Characteristics
(16821A, 16822A, and 16823A)
Agilent 10469A 5 volt PECL data pod
Output type 100EL90 (5 V) with 348 ohm pulldown to
ground and 42 ohm in series
Maximum clock 300 MHz
Skew [1] Typical < 500 ps; worst case = 1 ns
Recommended lead set Agilent 10498A
Agilent 10471A 3.3-volt LVPECL data pod
Output type 100LVEL90 (3.3 V) with 215 ohm pulldown
to ground and 42 ohm in series
Maximum clock 300 MHz
Skew [1] Typical < 500 ps; worst case = 1 ns
Recommended lead set Agilent 10498A
Agilent 10473A 3-State 2.5-volt data pod
Output type 74AVC16244
3-state enable Negative true, 38 KΩ to GND, enabled
on no connect
Maximum clock 300 MHz
Skew [1] Typical < 1.5 ns; worst case = 2 ns
Recommended lead set Agilent 10498A
[1] Typical skew measurements made at pod connector with approximately
10 pF/50 KΩ load to GND; worst case skew numbers are a calculation of worst
case conditions through circuits. Both numbers apply to any channel within the
pattern generator.
[2] Channel 7 on the 3-state pods has been brought out in parallel as a non 3-state
signal. By looping this output back into the 3-state enable line, the channel can be
used as a 3-state enable.
74AVC16244
42 Ω
348 Ω
100EL90
42 Ω
215 Ω
100LVEL90