Specifications

14
Pattern Generator Specifications and Characteristics
(16821A, 16822A, and 16823A)
Agilent 10465A ECL data pod (unterminated)
Output type 10H115 (no termination)
Maximum clock 300 MHz
Skew [1] Typical < 1 ns; worst case = 2 ns
Recommended lead set Agilent 10347A
Agilent 10466A 3-state TTL/3.3 volt data pod
Output type 74LVT244 with 100 series;
10H125 on non 3-state channel 7 [2]
3-state enable Negative true, 100 K to GND, enabled
on no connect
Maximum clock 200 MHz
Skew [1] Typical < 3 ns; worst case = 7 ns
Recommended lead set Agilent 10474A
[1] Typical skew measurements made at pod connector with approximately
10 pF/50 Kload to GND; worst case skew numbers are a calculation of worst
case conditions through circuits. Both numbers apply to any channel within the
pattern generator.
[2] Channel 7 on the 3-state pods has been brought out in parallel as a non 3-state
signal. By looping this output back into the 3-state enable line, the channel can be
used as a 3-state enable.
10H115
100
74LVT244