Agilent 16800 Series Portable Logic Analyzers Data Sheet Quickly debug, validate, and optimize your digital system – at a price that fits your budget.
Selection Guide for 16800 Series Portable Logic Analyzers 16801A, 16821A1 16802A, 16822A1 16803A, 16823A1 16804A 16806A Agilent Model Number Logic analyzer channels 34 68 102 136 204 Pattern generator channels1 48 48 48 N/A N/A High-speed timing zoom 4 GHz (250 ps) with 64 K depth Maximum timing sample rate (Half/full ch) 1.0 GHz (1.0 ns) / 500 MHz (2.
Logic Analysis for Tracking Real-time System Operation Agilent 16800 Series portable logic analyzers offer the performance, applications, and usability your digital development team needs to quickly debug, validate, and optimize your digital system – at a price that fits your budget.
Logic Analysis for Tracking Real-time System Operation Automate measurement setup and quickly gain diagnostic clues 16800 Series logic analyzers make it easy for you to get up and running quickly by automating your measurement setup process. In addition, the logic analyzer’s setup/hold window (or sampling position) and threshold voltage settings are automatically determined so you can capture data on high-speed buses with the highest accuracy. Auto Threshold and Sample Position mode allow you to...
Agilent 16800 Series Logic Analyzer Specifications and Characteristics Channel count per measurement mode 16801A/16821A 16802A/16822A 16803A/16823A 16804A 16806A State analysis [1] 32 data + 2 clocks 64 data + 4 clocks 98 data + 4 clocks 132 data + 4 clocks 200 data + 4 clocks Conventional timing 34 68 102 136 204 Transitional timing for sample rates < 500 MHz 34 68 102 136 204 Transitional timing for 500 MHz sample rate – 34 68 102 170 [1] Unused clock channels can be used as
Agilent 16800 Series Logic Analyzer Specifications and Characteristics State (synchronous) analysis mode Option 250 Option 500 (available on 16802A, 16803A, 16804A, 16806A, 16822A and 16823A) tWidth* [1] 1.5 ns 1.5 ns tSetup 0.5 tWidth 0.5 tWidth tHold 0.5 tWidth 0.5 tWidth tSample range [2] –3.2 ns to +3.2 ns –3.2 ns to +3.
Agilent 16800 Series Logic Analyzer Specifications and Characteristics State (synchronous) analysis mode Option 250 Option 500 (available on 16802A, 16803A, 16804A, 16806A, 16822A and 16823A) Clock qualifier setup time 500 ps N/A Clock qualifier hold time 0 N/A Time tag resolution 2 ns 1.
Agilent 16800 Series Logic Analyzer Specifications and Characteristics Timing (asynchronous) analysis mode Conventional timing Transitional timing [8] Sample rate on all channels 500 MHz 500 MHz Sample rate in half channel mode 1 GHz N/A Number of independent analyzers [5] 2 (1 for 16801A or 16821A) 2 (1 for 16801A or 16821A) Sample period (half channel) 1.0 ns N/A Minimum sample period (full channel) 2.0 ns 2.0 ns Minimum data pulse width 1 sample period + 1.0 ns 1 sample period + 1.
Agilent 16800 Series Logic Analyzer Specifications and Characteristics Timing (asynchronous) analysis mode Conventional timing Transitional timing Trigger resources 16 patterns evaluated as =, =/, >, ≥, <, ≤ 14 double-bounded ranges evaluated as in range, not in range 3 edge/glitch 1 timer for every 34 channels (no timer for 16801A or 16821A) 2 global counters 1 occurrence counter per sequence level 4 flags 15 patterns evaluated as =, =/, >, ≥, <, ≤ 14 double-bounded ranges evaluated as in range, not
A Built-in Pattern Generator Gives You Digital Stimulus and Response in a Single Instrument Selected 16800 Series models (16821A, 16822A and 16823A) also include a 48-channel pattern generator to drive down risk early in product development.
A Built-in Pattern Generator Gives You Digital Stimulus and Response in a Single Instrument “Wait for External Event…” for input pattern The clock pod also accepts a 3-bit input pattern. These inputs are level-sensed so that any number of “Wait for External Event” instructions can be inserted into a stimulus program. Up to four pattern conditions can be defined from the OR-ing of the eight possible 3-bit input patterns. A “Wait for External Event” also can be defined to wait for an Arm.
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) Pattern generator characteristics Maximum memory depth 16 MVectors Number of output channels at > 180 MHz and ≤ 300 MHz clock 24 Number of output channels at ≤ 180 MHz clock 48 Number of different macros Limited only by the pattern generator’s available memory depth Maximum number of lines in a macro Maximum number of parameters in a macro Maximum number of macro invocations Maximum loop count in a repeat loop Maximum
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) Data pod characteristics Note: Data pod output parametrics depend on the output driver and the impedance load of the target system. Check the device data book for the specific drivers listed for each pod.
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) Agilent 10465A ECL data pod (unterminated) Output type 10H115 (no termination) Maximum clock 300 MHz Skew [1] Typical < 1 ns; worst case = 2 ns 10H115 Recommended lead set Agilent 10347A Agilent 10466A 3-state TTL/3.
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) Agilent 10469A 5 volt PECL data pod Output type 100EL90 (5 V) with 348 ohm pulldown to ground and 42 ohm in series Maximum clock 300 MHz Skew [1] Typical < 500 ps; worst case = 1 ns 100EL90 42 Ω 348 Ω Recommended lead set Agilent 10498A Agilent 10471A 3.3-volt LVPECL data pod Output type 100LVEL90 (3.
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) Agilent 10476A 3-state 1.8-volt data pod Output type 74AVC16244 3-state enable Negative true, 38 KΩ to GND, enabled on no connect Maximum clock 300 MHz Skew [1] Typical < 1.5 ns; worst case = 2 ns 74AVC16244 Recommended lead set Agilent 10498A Agilent 10483A 3-state 3.
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) Data cable characteristics without a data pod The pattern generator data cables without a data pod provide an ECL terminated (1 KΩ to –5.2 V) differential signal (from a type 10E156 or 10E154 driver). These are usable when received by a differential receiver, preferably with a 100 Ω termination across the lines.
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) Clock cable characteristics without a clock pod The pattern generator clock cables without a clock pod provide an ECL terminated (1 KΩ to –5.2 V) differential signal (from a type 10E164 driver). These are usable when received by a differential receiver, preferably with a 100 Ω termination across the lines.
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) Clock pod characteristics 10460A TTL clock pod Clock output type 10H125 with 47 Ω series; true & inverted Clock output rate 100 MHz maximum Clock out delay Approximately 8 ns total in 14 steps Clock input type TTL – 10H124 Clock input rate DC to 100 MHz Pattern input type TTL – 10H124 (no connect is logic 1) Clock-in to clock-out Approximately 30 ns Pattern-in to recognition Approximately 15 ns + 1 clk period R
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) 10468A 5-volt PECL clock pod Clock output type 100EL90 (5V) with 348 ohm pulldown to ground and 42 ohm in series Clock output rate 300 MHz maximum Clock out delay Approximately 8 ns total in 14 steps Clock input type 100EL91 PECL (5V), no termination Clock input rate DC to 300 MHz Pattern input type 100EL91 PECL (5V), no termination (no connect is logic 0) 100EL90 Clock-in to clock-out Approximately 30 ns Pattern
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) 10472A 2.5-volt clock pod Clock output type 74AVC16244 Clock output rate 200 MHz maximum Clock out delay Approximately 8 ns total in 14 steps Clock input type 74AVC16244 (3.6V max) Clock input rate DC to 200 MHz Pattern input type 74AVC16244 (3.
Pattern Generator Specifications and Characteristics (16821A, 16822A, and 16823A) 10477A 3.3-volt clock pod Clock output type 74AVC16244 Clock output rate 200 MHz maximum Clock out delay Approximately 8 ns total in 14 steps Clock input type 74AVC16244 (3.6V max) Clock input rate DC to 200 MHz Pattern input type 74AVC16244 (3.
Unleash the Complementary Power of a Logic Analyzer and an Oscilloscope Seamless scope integration with View Scope Easily make time-correlated measurements between Agilent logic analyzers and oscilloscopes. The time-correlated logic analyzer and oscilloscope waveforms are integrated into a single logic analyzer waveform display for easy viewing and analysis.
Get Instant Insights into your Design with Multiple Views and Analysis Tools Acquisition and analysis tools provide rapid insight into your toughest debug problems You have unique measurement and analysis needs. When you want to understand what your target is doing and why, you need acquisition and analysis tools that rapidly consolidate data into displays that provide insight into your system’s behavior. Figure 5.
Get Instant Insights into your Design with Multiple Views and Analysis Tools Save time analyzing your unique design with a turnkey setup Agilent Technologies and our partners provide an extensive range of bus and processor analysis probes. They provide non-intrusive, full-speed, real-time analysis to accelerate your debugging process.
16800 Series Instrument Characteristics Standard data views Waveform Integrated display of data as digital waveforms, analog waveforms imported from an external oscilloscope, and/or as a chart of a bus’ values over time Listing Displays data as a state listing Compare Compares data from different acquisitions and highlights differences Source code Displays time-correlated source code and inverse assembly simultaneously in a split display Define the trigger event by simply clicking on a line of sourc
16800 Series Instrument Characteristics 16800 Series PC characteristics Operating system Microsoft Windows® XP Professional Processor Intel Celeron™ 2.93 GHz Chipset Intel 915G System memory 1 GB SDRAM Hard disk drive 80 GB (or higher) Installed on hard drive Operating system, latest revision of the logic analyzer application software, optional application software ordered with the logic analyzer 16800 Series instrument controls LCD display Large 38.1-cm (15-in.
16800 Series Instrument Characteristics Programmability You can write programs to control the logic analyzer application from remote computers on the local area network using COM or ASCII. The COM automation server is part of the logic analyzer application. This software allows you to write programs to control the logic analyzer. All measurement functionality is controllable via the COM interface. LAN connection Figure 6.
16800 Series Interfaces Peripheral interfaces Display 15-pin VGA connector Keyboard PS/2 Mouse PS/2 Parallel 25-pin D-sub Serial 9-pin D-sub PCI card expansion slot 1 full profile USB Six 2.
16800 Series Physical Characteristics 443.23 (17.450) Dimensions Power 16801A 16802A 16803A 115/230 V, 48-66 Hz, 605 W max 115/230 V, 48-66 Hz, 605 W max 115/230 V, 48-66 Hz, 605 W max 16804A 16806A 16821A 16822A 16823A 115/230 V, 48-66 Hz, 775 W max 115/230 V, 48-66 Hz, 775 W max 115/230 V, 48-66 Hz, 775 W max 115/230 V, 48-66 Hz, 775 W max 115/230 V, 48-66 Hz, 775 W max Weight Max net Max shipping 16801A 12.9 kg (28.5 lbs) 19.7 kg (43.5 lbs) 16802A 13.2 kg (28.9 lbs) 19.9 kg (43.
16800 Series Accessories Agilent 1184A Testmobile The Agilent 1184A testmobile gives you a convenient means of organizing and transporting your logic analyzer and accessories. The testmobile includes the following: • Drawer for accessories (probes, cables, power cords) • Keyboard tray with adjustable tilt and height Figure 11.
16800 Series Accessories Rack accessories Stationary shelf This light-duty fixed shelf is designed to support 16800 Series logic analyzers. The shelf can be used in all standard Agilent racks. The stationary shelf is mounted securely into place using the supplied hardware and is designed to sit at the bottom of the EIA increment.
Ordering Information Each 16800 Series portable logic analyzer comes with one PS/2 keyboard, one PS/2 mouse, accessory pouch, power cord and 1-year warranty standard.
Ordering Information 16800 Series probing options 16800 Series logic analyzer probes Logic analyzer probes are ordered separately. Please specify probes when ordering to ensure the correct connection between your logic analyzer and the device under test.
Ordering Information Upgrade memory depth or state speed after purchase Logic analyzer channels Logic analyzer models 34 16801A 16821A 68 16802A 16822A 102 16803A 16823A 136 16804A 204 16806A After purchase upgrade models E5876A E5877A E5878A E5879A E5880A Memory depth 1 M: -001 4 M: -004 16 M: -016 32 M: -032 State speed * 450 MHz: -500* Applies to 68, 102, 136 and 204 channel models Related Literature Publication Title
www.agilent.com Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully.