Specifications

15
10H115
100
74LVT244
42
348
100EL90
42
215
100LVEL90
Pattern Generator Specifications and Characteristics
(16821A, 16822A, and 16823A) (continued)
Agilent 10465A ECL data pod (unterminated)
Output type 10H115 (no termination)
Maximum clock 300 MHz
Skew
1
Typical < 1 ns; worst case = 2 ns
Recommended lead set Agilent 10347A
Agilent 10466A 3-state TTL/3.3 volt data pod
Output type 74LVT244 with 100 Ω series;
10H125 on non 3-state channel 7
2
3-state enable Negative true, 100 KΩ to GND,
enabled on no connect
Maximum clock 200 MHz
Skew
1
Typical < 3 ns; worst case = 7 ns
Recommended lead set Agilent 10474A
Agilent 10469A 5 volt PECL data pod
Output type 100EL90 (5 V) with 348 ohm pulldown
to ground and 42 ohm in series
Maximum clock 300 MHz
Skew
1
Typical < 500 ps; worst case = 1 ns
Recommended lead set Agilent 10498A
Agilent 10471A 3.3-volt LVPECL data pod
Output type 100LVEL90 (3.3 V) with 215
pulldown to ground and 42 in
series
Maximum clock 300 MHz
Skew
1
Typical < 500 ps; worst case =
1 ns
Recommended lead
set
Agilent 10498A
1. Typical skew measurements made at pod connector with
approximately 10 pF/50 KΩ load to GND; worst case skew
numbers are a calculation of worst case conditions through
circuits. Both numbers apply to any channel within the
pattern generator.
2. Channel 7 on the 3-state pods has been brought out in parallel
as a non 3-state signal. By looping this output back into the
3-state enable line, the channel can be used as a 3-state
enable.