Specifications

10
Timing (asynchronous)
analysis mode
Conventional timing Transitional timing
Trigger resources 16 patterns evaluated as =, =/, >, ≥, <, ≤
14 double-bounded ranges evaluated as
in range, not in range
3 edge/glitch
1 timer for every 34 channels (no timer
for 16801A or 16821A)
2 global counters
1 occurrence counter per sequence level
4 flags
15 patterns evaluated as =, =/, >, ≥, <, ≤
14 double-bounded ranges evaluated as in
range, not in range
3 edge/glitch
1 timer for every 34 channels (no timer for
16801A or 16821A)
2 global counters
1 occurrence counter per sequence level
4 flags
Trigger resource conditions Arbitrary Boolean combinations Arbitrary Boolean combinations
Trigger actions Go To
Trigger, send e-mail, and fill memory
Trigger and Go To
Turn on/off default storing
Timer start/stop/pause/resume
Global counter increment/decrement/
reset
Occurrence counter reset
Flag set/clear
Go To
Trigger, send e-mail, and fill memory
Trigger and Go To
Turn on/off default storing
Timer start/stop/pause/resume
Global counter increment/decrement/
reset
Occurrence counter reset
Flag set/clear
Maximum global counter 2E+24 2E+24
Maximum occurrence counter 2E+24 2E+24
Maximum range width 32 bits 32 bits
Maximum pattern width Smaller of 128 bits or maximum number of
channels
Smaller of 128 bits or maximum number of
channels
Timer value range 60 ns to 2199 seconds 60 ns to 2199 seconds
Timer resolution 2 ns 2 ns
Timer accuracy ± (5 ns +0.01%) ± (5 ns +0.01%)
Greater than duration 4.0 ns to 67 ms in 4.0 ns increments 4.0 ns to 67 ms in 4.0 ns increments
Less than duration 8.0 ns to 67 ms in 4.0 ns increments 8.0 ns to 67 ms in 4.0 ns increments
Timer reset latency 60 ns 60 ns
Agilent 16800 Series Logic Analyzer Specifications and Characteristics
(continued)