System information

34
16600A 16517A/ 16550A 16554A 16555A/D 16556A/D
Series 16518A
Maximum Clocked 64 Kbits 64 Kbits 8 Kbits 512 Kbits 1 Mbit/2 Mbits 1 Mbit/2 Mbits
serial Data
[1]
trace Unclocked 32 Kbits 16-32 Kbits 2 Kbits 256 Kbits 1 Mbit 1 Mbit
depth Data
[2]
Maximum Clocked 100 Mbits/s 1 Gbit /s 100 Mbits/s 70 Mbits/s 110 Mbits/s 100 Mbits/s
serial bus Data
[3]
frequency Unclocked 62.5 Mbits/s 1 Gbit /s 125 Mbits/s 62.5 Mbits/s 125 Mbits/s 100 Mbits/s
Data
[4]
Minimum Clocked No limit 20 Mbits/s No limit No limit No limit No limit
serial bus Data
frequency Unclocked 500 bits/s 765 bits/s 6 bits/s 500 bits/s 1.25 Kbits/s 1.25 Kbits/s
Data
[5]
controlled by the user independent
of the serial analysis tool.
Because every trace is nonintru-
sive, and every event captured in
the trace is time-stamped, you can
correlate activity from your serial
bus with other events in the target
system.
The Agilent Technologies 16522A
pattern generator module can be
used to generate your own serial
test data.
Maximum Parallel Word Width
32 bits
Parallel Data Display Types
Binary, Octal, Hex, Decimal,
ASCII, Twos Complement
Off-Line Analysis and
Post-Processing
All measurements can be saved
using the file out tool. Data can be
recalled at any time for later analy-
sis using any analysis or display
tool. Serial measurement data can
be exported to your host computer
as ASCII files.
Product Characteristics
Data Sources
All state and timing measurement
modules supported by the 16700A
Series logic analysis systems serve
without modification as data
sources for the B4601B serial
analysis tool set. The particular
measurement module used deter-
mines time resolution and accura-
cy. Sample rate, channel count,
memory depth and triggering are
The Serial Analysis
Tool Set (continued)
16557D 16710A/711A/712A 16715A 16716A 16717A
Maximum Clocked 2 Mbits 8 Kbits/32 Kbits/128 Kbits 2 Mbits 512 Kbits 2 Mbits
serial Data
[1]
trace Unclocked 1 Mbit 4 Kbits/16 Kbits/64 Kbits 1 Mbit 256 Kbits 1 Mbit
depth Data
[2]
Maximum Clocked 135 Mbits/s 100 Mbits/s 167 Mbits/s 167 Mbits/s 333 Mbits/s
serial bus Data
[3]
frequency Unclocked 125 Mbits/s 125 Mbits/s 167 Mbits/s 167 Mbits/s 167 Mbits/s
Data
[4]
Minimum Clocked No limit No limit No limit No limit No limit
serial bus Data
frequency Unclocked 5 Kbits/s 5 Kbits/s 50 bits/s 50 bits/s 50 bits/s
Data
[5]
Information in Table 3 calculated according to notes [1] to [5]:
[1] =Maximum State Memory Depth
[2] =Maximum Timing Memory Depth/4
[3] =Maximum State Frequency
[4] =Maximum Timing Frequency/4
[5]=1/(Maximum sample period x 20)
Table 3. Serial Measurement Characteristics.