Specifications

79
Chapter 1: Agilent Technologies 16700A/B-Series Logic Analysis System
Overview - Multiple Frames Configuration
In addition to the Group Run Arming Tree configuration shown below,
configure analyzers 1 and 2 with the OR Trigger macro.
Two frames; Two analyzers; Group Run
In this Multi-frame example, both frames are armed by the "Group Run"
option. When Analyzer 1 triggers, it passes the arm signal to Multi-
frame 1 (Mf1). Mf1 then passes the arm signal to Mf2, which in turn
passes the arm signal to Analyzer 2.
Multi-frame Error and Warning Messages
Illegal cable connection
The Multi-frame module must be daisy chain cabled. For an N-Frame
Multi-frame setup, there are N-1 cables.
In the pictured example there are 3 frames. Frame 1 is the master
frame. The master frame has no input cable. There must always be one
and only one master frame.