Specifications

77
Chapter 1: Agilent Technologies 16700A/B-Series Logic Analysis System
Overview - Multiple Frames Configuration
arm signal to Multi-frame 1 (MF1). Mf1 passes the arm signal to Mf2.
Mf2 then passes the arm signal to any/all analyzers participating in the
OR Trigger arrangement (Analyzer 2 in this example).
If Analyzer 2 triggers first, it passes the arm signal to Mf2. Mf2 then
passes the arm signal to Mf1, which passes the arm signal to Analyzer
1.
In addition to the Group Run Arming Tree configuration shown below,
configure analyzer 1 and 2 with the OR Trigger macro.
Two frames; Three analyzers; Group Run OR
Trigger
In this Multi-frame example, if Analyzer 2 triggers first, it passes the
arm signal to Multi-frame 2 (Mf2). Mf2 then passes the arm signal to
Mf1, which in turn passes the arm signal to Analyzer 1. Analyzer 1 then
passes the arm signal to Analyzer 3.
If Analyzer 1 triggers first, it passes the arm signal to Multi-frame 1
(Mf1) and Analyzer 3. Mf1 then passes the arm signal to Mf2, which in
turn passes the arm signal to Analyzer 2.
In addition to the Group Run Arming Tree configuration shown below,
configure analyzers 1 and 2 with the OR Trigger macro.