Specifications

71
Chapter 1: Agilent Technologies 16700A/B-Series Logic Analysis System
Overview - Multiple Frames Configuration
Overview - Multiple Frames Configuration
The Multi-frame module consists of a hardware module and a cable. It
is used to expand the total number of measurement module slots for
advanced measurements that may require the following:
High channel count
Centralized Run/Stop control
Time correlated data displays
Cross-frame flag signaling and trigger arming
Multi-frame modules are installed into slot 1 of the mainframe (B-series
only). Up to eight 16700B/16702B mainframes can be connected
together in a Multi-frame group. Each 16700B/16702B mainframe can
in turn have one 16701B expansion frame connected to it, allowing for
a total of up to 80 measurement module slots and 16 emulation module
slots. One Multi-frame module is required for each frame connected
into the Multi-frame group.
For more information on installing Multi-frame modules, see Multi-
frame Installation (see page 80).
NOTE: As with any intermodule measurement involving multiple measurement
modules, each module must be configured properly and be able to run on its
own as a separate module. This will eliminate many problems when you run
them together as a group.
For a typical Multi-frame configuration, setup the following three areas:
1. Multi-frame Configuration
2. Intermodule Configuration
3. Analyzer Trigger Configuration
1. Multi-frame
Configuration
When a Multi-frame module is installed in the frame, a Multi-frame icon
appears in the System window, positioned in the option slot of the rear
panel graphic. Select this icon to access the Multi-frame Config dialog.