Specifications
151
Chapter 1: Agilent Technologies 16700A/B-Series Logic Analysis System
The System Administration Tools
Self-Test....
2. Read the Question dialog and select Yes if you wish to run the self tests.
3. From the Self Test window, select the desired area to test by selecting the
appropriate tab. Your choices are either the System boards, modules in the
Master Frame, or modules in the optional Expander Frame.
4. Run the tests in one of the following ways:
• Test All – To test all boards or modules under a tab, select Test All at
the bottom of the Self Test window.
• Test a single board or module – To test a single board or module under
a tab, select the desired board or module, and then select either a
single component or select Test All at the bottom of the board or
module test dialog.
5. When you are finished running self tests, select Quit. Then restart your
session from the Session Manager window.
NOTE: For complete information on self tests, test options, troubleshooting, and
service procedures, refer to the optional service guides available for the
system or the desired modules.
See Also “More on Self Tests” on page 151
More on Self Tests
Self Test lets you get confidence that the hardware is configured and
operating correctly, and enables the HP factory to test the product.
Self Tests and Session Management
When Self Test is entered, the current measurement session is exited.
You are warned of this prior to entering Self Test so you can save any
important data and configurations. The closure of the measurement
session is necessary because Self Test leaves the hardware in an
unknown state when it is finished. Restarting the measurement session
is then required to properly initialize the hardware.
Testing Multi-Card Modules
Under each tab is a list of boards or measurement modules. When