Installation guide

Table Of Contents
61
Chapter 5: Introduction to State Analysis: Trigger on an Event
Set Up the State Analyzer
Set Up the State Analyzer
First you must change the analyzer type from timing to state. Changing
the analyzer type to state allows you to set up the clock as well as set
up more complex triggers using ranges and combinations of values.
1 Click on the analyzer you have connected to the credit card
board.
2 Select Setup... from the pop-up menu to activate that
instrument.
3 Click on the Sampling tab.
4 Select State Mode.
Each pod has one clock channel. The clock channel on pod 1 is J. We
will set J to sample data on the falling edge.