5 Setting Up Multiframe Configurations
Run the Agilent Logic Analyzer application on your remote PC and
connect to the multiframe system by going online and connecting to the
frame. With this option:
Your performance may vary because analyzer data from all logic
analysis frames must be sent over LAN to your locally running
application.
Simple 2-Frame w/Crossover Cable Configuration
When you have only two frames in the simple 100 Base- T multiframe
configuration (see page 85), you can gain performance by connecting a
crossover cable between the frames’ 1000 Base- T ports and configuring
these ports with static IP addresses.
If you have a 1000 Base- T switch, use the simple 1000 Base- T multiframe
configuration instead (see page 86).
Interface to Corporate LAN
100 Base-T Switch
Multiframe Cable
Cross-over Cable Between
1000 Base-T Interfaces
16901A/902A/902B (must be at least 1)
16900A/901A/902A/902B