1280C GB 20001204
12 Fill the tanks up to the marking with ready-mixed fixer or developer.
13 Make sure to check the numbers which mark the roller sets, the tank covers and
their corresponding tanks.
14 Place the roller sets back in the corresponding tanks (refer to the identification
number labels).
Take care not to spill any fixer into the developer tank. Otherwise, clean the
developer tank again and rinse it thoroughly.
Make sure to place all elements back to their appropriate location. Refer to
‘Overview and location of identification labels.’ on page 53.