Specifications

52
1280C GB 20001204
Survey of the preventive maintenance work
Preventive maintenance and cleaning of the Classic E.O.S. at regular intervals
will keep the Classic E.O.S. running smoothly and ensure optimum processing
quality.
A survey of this cleaning and maintenance work is listed in the table below. The
procedures themselves are explained in detail in this chapter.
Interval Maintenance work Page
Daily
Clean the feed table.
54
If possible, switch the Classic E.O.S. off overnight.
20
Weekly Clean the tank covers and film guide elements.
56
Monthly
Check the ground fault switch.
Every three
months
Clean the tanks and roller sets.
59
Clean the squeegee roller set.
66
Clean the pumps.
68
Clean the dryer roller sets.
Procedure for skilled service personnel only.
97
Every six
months
Cleaning the water filter.
104
Yearly
Have the rack bearings and gears checked by your local service
organization.
Ad hoc
Clean the film scanner.
54
Have the replenishment settings checked by your local service
organization.
Have the rack bearings and gears checked by your local service
organization.
If you do not comply with the above-mentioned maintenance instructions,
there might be a loss of photographic quality. If the processor is not main-
tained correctly, the proper functioning and the safe operation of the
machine are no longer guaranteed.