Specifications

45
1280C GB 20001204
Standby developer and fixer replenishment
(jog cycle)
In order to compensate for oxidation of chemicals during a protracted standby
period, an additional replenishment of developer and fixer can be initiated auto-
matically every hour (‘jog cycle’ function).
The default setting is AUTO: the jog cycle will be automatically switched ON or
OFF in accordance with your daily film consumption: ON if the consumption is
less than 3 m² per day, OFF if the consumption is more than 3 m² per day.
Refer to the table for recommended jog cycle settings, depending on the specific
workload.
Related setting: Developer replenishment rate
more than 5 m² film/day 3 to 5 m² film/day less than 3 m² film/day
daily use irregular use daily use irregular use daily use irregular use
400 ml/m² 400 ml/m² 600 ml/m² 600 ml/m² 600 ml/m² 600 ml/m²
Standby developer and fixer replenishment - jog cycle
more than 5 m² film/day 3 to 5 m² film/day less than 3 m² film/day
daily use irregular use daily use irregular use daily use irregular use
OFF OFF OFF OFF ON ON
Related setting: Start-up replenishment function
more than 5 m² film/day 3 to 5 m² film/day less than 3 m² film/day
daily use irregular use daily use irregular use daily use irregular use
OFF ON OFF ON OFF ON
The jog cycle is not adjustable during film processing.
If you do not comply with the recommended replenishment rates, the
optimal processing stability is no longer guaranteed and sensitometric
variations might occur.