When to adjust the processing parameters
You may want to adjust the processing parameters
• when environmental conditions change, e.g. relative humidity or room tempera-
ture,
• when other chemicals will be used,
• when another type of film will be used.
Overview of recommended settings
The table below lists the recommendations for optimal processing stability,
depending on your specific workload.
(*)The default setting is AUTO: the developer and fixer jog cycle is set automati-
cally ON if the daily film consumption is less than 3 m². It is set automatically
OFF if the daily film consumption is more than 3 m².
Changing some of the parameters can have a negative effect on the image
quality. Always consult your local service organization.
Developer replenishment rate
more than 5 m² film/day 3 to 5 m² film/day less than 3 m² film/day
daily use irregular use daily use irregular use daily use irregular use
400 ml/m² 400 ml/m² 600 ml/m² 600 ml/m² 600 ml/m² 600 ml/m²
Standby developer and fixer replenishment - jog cycle (*)
more than 5 m² film/day 3 to 5 m² film/day less than 3 m² film/day
daily use irregular use daily use irregular use daily use irregular use
OFF OFF OFF OFF ON ON
Start-up replenishment function
more than 5 m² film/day 3 to 5 m² film/day less than 3 m² film/day
daily use irregular use daily use irregular use daily use irregular use
OFF ON OFF ON OFF ON