Specifications

27
1280C GB 20001204
Recommended chemicals
The tables below list the recommended chemicals, as a function of the process-
ing cycle, temperature level and the replenishment quantity.
The replenishment quantities as listed in the above table are valid only if your
film consumption exceeds 5 m
2
film/day and is based on a regular daily use. If
your daily film consumption is lower, you can initiate a chemical jog cycle, which
provides additional replenishment rates that compensate for low film usage.
Refer to chapter 4, ‘Customization’.
Chemicals Developer and fixer temperature
HT IP RP
Developer G 138 i 38 ° C 37 ° C 34 ° C
Fixer G 334 i/
G338
34 ° C 34 ° C 34 ° C
Chemicals Replenishment quantity
HT / IP / RP
Developer G 138 i
400 ml/m
2
Fixer G 334 i/
G338
400 ml/m
2
When handling chemicals, make sure to take notice of the warning instruc-
tions on the packing material. Refer to ‘Special instructions for the handling
of chemicals’ on page 8.